The following circuit sections are built onto a single Eurocard, 199x100x12TE with
SMD-technology:
3-phase power supply with smoothing capacitors (-P-)
single phase supply (any phase with the rated voltage, possibly with extra
smoothing capacitance) is possible
fuses for DC-link, ballast circuit and auxiliary power supply
ballast circuit with -w- characteristic
4-quadrant output stage (V-MOS transistors)
auxiliary supply, optionally (solder links) supply from the DC-link
or an external 24 V DC source
2 differential setpoint inputs
input for DC tacho
Enable input
limit-switch inputs positive / negative
integral-off input for driving up to a fixed stop monitoring for actual current value
PI current and speed controller
trimmer potentiometer and fixed components for all important settings
solder links for changing to IxR compensation for optional operation with
tachometer or armature voltage control
24 V logic with electrically isolated optocouplers for the control signals, PLC-compatible
system ready (BTB) relay with floating contact
display LEDs for operational readiness / fault
15 V auxiliary voltage outputs, 20 mA
Protective and monitoring functions
protected from short-circuit / earth short on the motor connection terminals
monitoring of the operating voltages
temperature monitoring of the output stage
fuse-protection of: ballast circuit, DC-link, auxiliary supply
monitoring of the amplifier and motor
overvoltage protection
Transport temperature/humidity see Chapter VI.1
Storage temperature/
humidity/duration see Chapter VI.1
Supply voltage tolerances
power stage
aux. supply (Option -24V-)
3x43V AC 10%
min. 20V DC / max. 30V DC referred to -GND
Ambient temperature TAMB.
in operation
0 … +45°C under rated conditions
+45 … +55°C with derating 2.5%/°C (forced convection)
Humidity in operation 5 … 85 % rel. humidity, no condensation
Site altitude up to 1000m a.m.s.l. without restriction
1000 … 2500m a.m.s.l. with derating 1.5%/100m
Pollution level pollution level 2 according to EN60204/EN50178
Protection class IP 00
Mounting location / position in closed switchgear cabinet / normally vertical
Ventilation cont. current < 8A
and TAMB. < 45°C
cont. current 8A
or TAMB. > 45°C
self-ventilating with natural convection (we always recommend
forced convection at higher loads or in narrow spaces).
forced convection
ensure that the incoming air is dust-free and that there is an
adequate supply of cooling air to the cabinet.
The prices of all products of Zhangzhou Fengyun may fluctuate at any time. The specific price is subject to the customer service quotation. Please confirm the model, product, price and other details with the customer service before placing the order. Second-hand and brand-new products are sold in the store. Please contact the customer service for details.
Recommended KOLLMORGEN related models:
KOLLMORGEN AKM21C-ANBNR-00 |
KOLLMORGEN AKM41S-ANS22-02 |
KOLLMORGEN AKM42E-EKGNR-01 |
KOLLMORGEN AKM44E-ANC2DB00 |
KOLLMORGEN AKM54K-ANC2AA00 |
KOLLMORGEN BJRL-20012-110001 |
KOLLMORGEN C25FE85B15-2500Z842 |
KOLLMORGEN CB06251 |
KOLLMORGEN CB06551 |
KOLLMORGEN CB06551 PRD-B040SSIB-63 |
KOLLMORGEN CB06560 |
KOLLMORGEN CB06560 PRD-B040SAIB-62 |
KOLLMORGEN CB06560 PRD-B040SAIB-62 |
KOLLMORGEN CB06561 |
KOLLMORGEN CB06561 PRD-B040SSLZ-62 |
KOLLMORGEN CE10560 |
KOLLMORGEN CP320260 |
KOLLMORGEN CR06200-000000 |
KOLLMORGEN CR06561-MZ |
KOLLMORGEN DIGIFAS 7202 |
KOLLMORGEN DIGIFAS 7202 |
KOLLMORGEN DIGIFAS7201 |
KOLLMORGEN E22SSLT-LNN-NS-04 |
KOLLMORGEN E33NCHA-LNN-NS-00 |
KOLLMORGEN E33NRHA-LNN-NS-00 |
KOLLMORGEN LE03565 |
KOLLMORGEN MMC-SD-2.0-230-D |
KOLLMORGEN MT308B1-E2C1 |
KOLLMORGEN PRD-0046000F-23 |
KOLLMORGEN PRD-0064DC-40-00 |
KOLLMORGEN PRD-B040SAIB-62 |
KOLLMORGEN PRD-B040SSIB-63 |
KOLLMORGEN PRD-B040SSLZ-62 |
KOLLMORGEN PRD-MZ205S0Z-10 |
KOLLMORGEN PRD-P303250Z-35 |
KOLLMORGEN PRD-P310250E-55 |
KOLLMORGEN PRD-P310250Z-55 |
KOLLMORGEN RMB-10V2-SYNQNET |
KOLLMORGEN S20260-SRS |
KOLLMORGEN S20330-SRS |
KOLLMORGEN S20360-SRS |
KOLLMORGEN S20660-SRS |
KOLLMORGEN S21260-SRS |
There are no reviews yet.