- AAll products on this website are discounted products, and market prices have been fluctuating. Please refer to customer service quotes for details. Pictures are not actual photos. Before placing an order, please confirm the model, product, price, and other detailed information with customer service. Both second-hand and brand new products are available for sale on this website. Please contact customer service for further communication.
-
Specifications Mass 3.2 kg (7.05 lb) Length 760 mm (29.9 in) Barrel length 196 mm (7.7 in)
Cartridge 9×19mm Parabellum Action Blowback, open bolt Rate of fire 450 rounds/min Muzzle velocity 365 m/s (1,198 ft/s) Effective firing range 100 m Feed system 32-round detachable box magazine for MP40 Sights Front blade, rear aperture
Kollmorgen SR55200-000000|Frequency converter servo controller|
- This section tells you how to install the drive on wall without vibration dampers. The degree of protection is IEC:IP00 and UL: open type.
- See the dimensions in chapter Dimensions and weights.Mark the locations for the four mounting holes.
- Drill the mounting holes.
- Insert wall plugs into the holes and start to screw bolts into the plugs. Drive the bolts deep enough into the
wall to make them carry the weight of the drive.
- Position the drive onto the bolts on the wall.
- Tighten the bolts securely in the wall.
When thyristor converters operate, the line voltage is short-circuited during commutation from one
thyristor to the next. This operation causes voltage dips in the mains PCC (point of common
coupling). For the connection of a power converter system to the mains, one of the following
configurations applies:
Configuration A
When using a converter, a minimum of impedance is required to ensure proper
performance of the snubber circuit. Use a line reactor to meet this minimum
impedance requirement. The value must therefore not drop below 1 % uk (relative
impedance voltage). It should not exceed 10 % uk, due to considerable voltage drops
at the converters outputs.
Configuration B
If special requirements have to be met at the PCC (standards like EN 61 800-3, DC
and AC drives at the same line, etc), different criteria must be applied for selecting a
line reactor. These requirements are often defined as a voltage dip in percent of the
nominal supply voltage. The combined impedance of ZLine and ZL1 constitute the total
series impedance of the installation. The ratio between the line impedance and the line
reactor impedance determines the voltage dip at the PCC. In such cases, line chokes
with an impedance around 4 % are often used.
Example calculation with ukLine = 1 % and ukL1 = 4 %:
Voltage dip = ZLine / (ZLine + ZL1) = 20 %. Detailed calculations see Technical guide.
Kollmorgen SR55200-000000|Frequency converter servo controller|
By structuring the information in this manner, the article provides a clear and organized understanding of input channels, transducer supply, and communication implementations in distributed control systems.
Zhangzhou Fengyun’s main products include ABB, GE, Bently Nevada Bentley, ICS TRIPLEX, Honeywell, Schneider, EPRO, yokogawa Yokogawa, Woodward, EMERSON, Emerson, and Invensys TRICONEX, which have abundant inventory, fast delivery, and reliable quality.