+86 15359293870 2804538582@qq.com
Industrial equipment parts procurement network

2MLF-AD16A Honeywell Pulse preamplifier controller

$2,580.00

In stock

model:2MLF-AD16A

Order (minimum order quantity): 1

Payment: telegraphic transfer
Port of shipment: Xiamen, Fujian
Hotline: 18165687102

E-mail:2804538582@qq.com

Listed here are the documents that contain general information for planning and implementing control hardware
and network communications in your Experion system:
• Control Hardware Planning Guide – Provides general information to assist you in planning and design of
control hardware in an Experion system. Control hardware includes C200 Controllers, Series A Chassis I/O
and FIMs, also, all I/O families, (except Series C I/O). It includes some supervisory network considerations
for general reference.
• C300 Controller Guide – This guide provides information that will assist you in planning and designing
activities, as well as the installation, operation, and troubleshooting of Series C300 Controllers in an
Experion system.
• Series C Fieldbus Interface Module (FIM) User Guide – Provides planning and implementation guide for the
Series C Fieldbus Interface Module.
• Fault Tolerant Ethernet Overview and Implementation Guide – Provides basic installation instructions and
configuration requirements for a Fault Tolerant Ethernet (FTE) network and its components.
• Fault Tolerant Ethernet Installation and Service Guide – Contains instructions for installing and configuring
a Fault Tolerant Ethernet (FTE) node. The guide includes troubleshooting and service information for an
FTE node.
• Fault Tolerant Ethernet Bridge Implementation Guide – Provides information for implementing a Fault
Tolerant Ethernet supervisory network through the FTE Bridge module. It includes module installation,
configuration, operation and service data.
• Process Manager I/O Troubleshooting and Maintenance Guide – Guide features notification messages (soft
fail codes and hard fail codes), service procedures and parts lists for PM I/O control hardware.

2MLF-AD16A Honeywell Pulse preamplifier controllerillustration

The following list compares previous features of the Process Manager I/O and the Series C I/O:

  • Non-Volatile Memory:

– In the PM, memory was maintained over a power cycle within the I/O card itself.

– With the Series C I/O, the configuration memory information is restored from the C300 controller at

power-up of the I/O Module.

  • IOL – The Series C I/O link runs at twice the speed of the PMIO I/O Link. Each C300 I/O Link can be

configured to provide Series-C or PMIO link speeds.

  • Series C I/O fully supports HART I/O. This includes the use of Secondary HART Variables as control

parameters.

  • Separation of Primary from Secondary modules:

– In the PM, the Primary and Secondary I/O Electronics modules could be separated, placed in different

cabinets, and/or powered by different power systems.

– Series C I/O does not have this capability.

  • Series C permits Zone 2 mounting of the Controller and I/O
  • In PMIO, the configuration memory is maintained only if a battery backup is installed.

The Experion Series C PIM is an interface between C300 Controller that enables high-accuracy pulse counting

of pulse streams from rotating machinery such as turbines, flow meters, and densitometers. High-accuracy and

repeatable measurement capability make the PIM well suited for metering and custody transfer applications.

The PIM has eight input channels. Out of the eight channels, some may be single consuming one channel or

dual consuming 2 adjacent channels. The last 2 channels (channel 7 and channel 8) can also be configured as

distinct Fast Cutoff using the two output channels on the module.

Each input channel has a 32-bit counter to perform pulse counting and frequency calculation. In addition, when

these channels are configured as single input channels, these eight channels also have a second 32-bit timer for

pulse period and pulse width measurement.

2.3.1 Features of PIM

The following are some of key the features of PIM.

  • Supports IOM redundancy.
  • Supports redundant module communications with the controller via IO link.
  • Supports simulation with SIM-C300 – The input value can be substituted by a program and/or UniSim using

the SIMVALUE parameter.

  • Supports high accuracy frequency, period, and pulse width measurement.
  • Provides hardware support for Meter Suite applications.
  • Provides connections to power field devices or pulse pre-amplifiers.
  • Supports pulse multiplexing that enables good pulses from a dual pulse input pair to be copied to the Prover

output interface.

  • Supports Dual Pulse Integrity in accordance with ISO6551:1996 Level A, which is required to support

interfacing of custody transfer meters with pulse outputs.

  • Provides the flexibility of configuring the eight input channels as single input, dual input, or a combination

of both single and dual input channels . For example you can configure the channels as;

– 2 single input channels, 3 dual input channels or

– 6 single input channels, 1 dual input channels.

For information on PIM specifications, refer to the Specifications document available on the Honeywell Online

Support site.

 

The prices of all products of Zhangzhou Fengyun may fluctuate at any time. The specific price is subject to the customer service quotation. Please confirm the model, product, price and other details with the customer service before placing the order. Second-hand and brand-new products are sold in the store. Please contact the customer service for details.

 

2MLF-AD16A Honeywell Pulse preamplifier controllerillustration1

Recommended HONEYWELL related models:

CC-MCAR01 HONEYWELL
CC-MCAR02 HONEYWELL
CC-PAIH01 HONEYWELL
CC-PAIH02 HONEYWELL
CC-PAIH51 HONEYWELL
CC-PAIM01 HONEYWELL
CC-PAIN01 HONEYWELL
CC-PAIX01 HONEYWELL
CC-PAIX02 HONEYWELL
CC-PAOH01 HONEYWELL
CC-PAON01 HONEYWELL
CC-PAOX01 HONEYWELL
CC-PCF901 HONEYWELL
CC-PCNT01 HONEYWELL
CC-PCNT02 HONEYWELL
CC-PCNT02 51454551-275 HONEYWELL
CC-PDIL01 HONEYWELL
CC-PDIL51 HONEYWELL
CC-PDOB01 HONEYWELL
CC-PDOD51 HONEYWELL
CC-PFB401 HONEYWELL
CC-TAID01 HONEYWELL
CC-TAID11 HONEYWELL
CC-TAIM01 HONEYWELL
CC-TAIN01 HONEYWELL
CC-TAIX01 HONEYWELL
CC-TAIX11 HONEYWELL
CC-TAON01 HONEYWELL
CC-TAOX01 HONEYWELL
CC-TAOX11 HONEYWELL
CC-TAOX61 HONEYWELL
CC-TCF901 HONEYWELL
CC-TCNT01 HONEYWELL
CC-TDIL01 HONEYWELL
CC-TDIL11 HONEYWELL
CC-TDIL51 HONEYWELL
CC-TDIL61 HONEYWELL
CC-TDOB01 HONEYWELL
CC-TDOB11 HONEYWELL
CC-TDOD51 HONEYWELL
CP-EXPIO HONEYWELL
DC3200-CE-200R-200-00000-00-0 HONEYWELL
FC-DCOM-232/485 HONEYWELL
FC-PSU-UNI2450U V1.0 HONEYWELL
FC-QPP-0002 HONEYWELL
FC-SAI-1620M HONEYWELL
FC-SAI-1620M V1.4 HONEYWELL
FC-SCNT01 HONEYWELL
FC-SDI-1624 HONEYWELL
FC-SDIL-1608 HONEYWELL
FC-SDO-0824 HONEYWELL
FC-SDO-0824 V1.3 HONEYWELL
FC-SDOL-0424 HONEYWELL



    Customers reviews

    There are no reviews yet.

    Be the first to review “2MLF-AD16A Honeywell Pulse preamplifier controller”

    Your email address will not be published. Required fields are marked *

    Search for products

    Back to Top
    Product has been added to your cart