+86 18065687102 2235954483@qq.com
Industrial equipment parts procurement network

Yokogawa YNT511D Data Collector/Control Power Module

$1,599.00

In stock

AAI543 Analog Output Module(4 to 20 mA, 16-Channel, Isolated)
AAV544 Analog Output Module(-10 to 10 V, 16-Channel, Isolated)
AAI835 Analog I/O Module(4 to 20 mA, 4-Channel Input/4-Channel Output, Isolated Channels)
AAV141 Analog Input Module (1 to 5 V, 16-Channel, Non-Isolated)
AAI841 Analog I/O Module(4 to 20 mA Input, 4 to 20 mA Output, 8-Channel Input/8-Channel Output, Non-Isolated)

SKU: YNT511D

PLC power lines, I/O power lines, input signal lines, output signal lines, AC lines, and DC lines should be wired separately as much as possible. The switch signal line and analog signal line should also be wired separately. Both switch signal line and analog signal line should use shielded wire, and the shielding layer should be reliably grounded. Due to the opposite direction of current in the twisted pair. Equally sized, it can cancel out the noise caused by induced currents. Therefore, signal wires are often twisted pair or shielded.

Yokogawa YNT511D Data Collector/Control Power Moduleillustration

The I/O Modules can be connected to field devices by terminal connection or with a terminal block via a KS cable interface adapter. A customer-furnished MIL cable can also be used to connect to the I/O Module. The following explains the terminal blocks as well as the signal wiring that can be paired with the I/O Modules.

A pressure clamp terminal block is provided for the terminal connection with field devices. To expand terminals via terminal boards, connect a KS cable adapter to an I/O Module. When using a customer-furnished MIL connector cable, can directly connect to an I/O Module.

Note: One dual-redundant terminal block is used to connect two adjacent I/O Modules.

Note: A cable connector cover (ACCC01) is provided for the connection via a MIL connector.

1: A cable can be connected directly to the I/O module without using an adapter.

2: For the combination of AAI135/AAI835/AAP135; ATK4A; AEA4D, either 2-Wire Transmitter 2-Wire Input (transmitter power supply type) or 4-Wire Transmitter 2-Wire Input (without transmitter power supply) can be selected for each input channel.

3: For the combination of AAI135/AAP135; ATI3A; AEA3D and the combination of AAI835; ATB3A; AEA3D, all input channels are 2-Wire Transmitter 2-Wire Input (transmitter power supply type).

4: When AAT145 module is connected to MTC terminal board or TETC terminal board, the module is 15-Channel.

 

Recommendation:
AAI143-H53/K4A00
AAI143-S00
AAI143-S00 S1
AAI143-S50/K4A00
AAI543-H00
AAI543-H50
AAI543-H50/A4S00
AAI543-H50/K4A00
AAI543-H61/K4A00
AAI543-H61/K4A00
AAI543-S00
AAI543-S00 S1
AAI835-S00 S2
AAI841-H03
AAI841-H53



    Customers reviews

    There are no reviews yet.

    Be the first to review “Yokogawa YNT511D Data Collector/Control Power Module”

    Your email address will not be published. Required fields are marked *

    Search for products

    Back to Top
    Product has been added to your cart